亚洲AV无码久久久久久精品同性,少妇人妻在线无码天堂视频网,中文字幕一区二区三区精华液,99999久久久久久亚洲,国内揄拍高清国内精品对白

EC019-SS K200門(mén)機現場(chǎng)故障解決指導書(shū)

2020/9/25 11:57:25點(diǎn)擊:


K200 門(mén)機現場(chǎng)故障解決
指導書(shū)
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
1. 現場(chǎng)反饋(Feed back):
1.1 K200 門(mén)機無(wú)強迫關(guān)門(mén)功能;
K200 door system has no the function of nudge closing ;
1.2 K200 門(mén)機編碼器和門(mén)機動(dòng)力線(xiàn)無(wú)屏蔽層,編碼器干擾大;
There exist at too much disturb signal for the encoder because of havn’t the shield wire of motor
cable and the encoder cable;
1.3 K200 門(mén)機密碼經(jīng)常進(jìn)不去,門(mén)機參數丟失以及檢修狀態(tài)下開(kāi)關(guān)門(mén)按鈕會(huì )出現失靈;
The password to control system of K200 are not available usally ,the control paramater have lost and
the open and colse door buttons can’t use when the door at the inspection mode;
1.4 關(guān)門(mén)過(guò)程中光幕被阻擋多次或門(mén)機被障礙物阻擋,導致失速撞門(mén)或門(mén)機脫離控制;
If cut the light curtain much times or keep blocking the door closed ,it will cause the fault running and
doors are knocked voilently;
1.5 門(mén)機門(mén)刀機械結構調整不到位,產(chǎn)生電梯運行時(shí)開(kāi)門(mén)現象以及電梯消防層門(mén)易發(fā)生開(kāi)門(mén)
不到位 情況;
The door vane mechanic system ajust not good ,it will cause to reopen the door during the lift start
running and the door of fire-risisted can’t open to the end of door width;
1.6 現場(chǎng)反映 K200 門(mén)機參數調試繁瑣;
There are too much adjusting parameters lead to testing difficulty ;
2. EC 測試和說(shuō)明(Testing and clarification by EC):
2.1 K200 門(mén)機無(wú)強迫關(guān)門(mén)功能 (問(wèn)題 1)。
K200 door system havn’t the function of nudge closing(Problem 1).
K200 門(mén)機系統作為標準配配置,無(wú)強迫關(guān)門(mén)功能。
In K200 door control system, nudging opertion is not a standard feature.
等級:C 頁(yè)碼:2/1
版本:A 更改碼:00
蒂森克虜伯電梯(中國區制造)
工程中心
K200 門(mén)機現場(chǎng)故障解決
指導書(shū)
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
注意(Note):
如果主板控制程序中設置了強迫關(guān)門(mén)功能,在門(mén)機被強行阻擋光幕的情況下會(huì )導致控制系統發(fā)出
強迫關(guān)門(mén)指令后無(wú)法按時(shí)收到門(mén)鎖接通信息,從而導致系統故障。
If there have the set the nudging running function at the mc2 control system,the mc2 control system will
sent the nudging order,but the door inverter havn’t accept and do the relative running at the light-curtain
is obstructed,it will cause the faultr.
處理方法(Solve methods):
請現場(chǎng)及時(shí)關(guān)閉 MC2 控制系統的強迫關(guān)門(mén)功能,在目前情況下,現場(chǎng)需要配置強迫關(guān)門(mén)功能,請
銷(xiāo)售人員請以非標項目進(jìn)行訂單處理。
We suggest to close the MC2 control system nudging running function.If the customer need to add the
nudging running function ,please to deal with the order at special order.
2.2 K200 門(mén)機編碼器和門(mén)機動(dòng)力線(xiàn)無(wú)屏蔽層,編碼器干擾大(問(wèn)題 2):
There exist at too much disturb signal for the encoder because of havn’t the shield wire of motor
cable and the encoder cable(Problem 2):
編碼器干擾問(wèn)題,已和 EC 試驗部的其他相關(guān)人員,對電梯運行過(guò)程中的編碼器信號,進(jìn)行多
次的 HIOKI 示波器測定,根據測試的波形結果,編碼器波形穩定、清晰。另一方面根據現場(chǎng)反
饋的方法,在工地現場(chǎng)將門(mén)機編碼器和門(mén)機動(dòng)力線(xiàn)臨時(shí)捆綁在一起,觀(guān)察運行電梯情況。測
試期間內電梯開(kāi)關(guān)門(mén)運行正常,未發(fā)現動(dòng)力線(xiàn)干擾編碼器的脈沖而影響門(mén)機運行。
To the encoder wired shield problem,the Testing & Filed support department have meaured the signal
of door motor encoder by the HIOKI wave recorder,The measued wave are stably and
clearly.According the feed back from the Branches,we are tight the power cable of door’s motor and
the encoder cable together,observe the elevator running ,the door system function are good ,the
distrubtion signal come form the motor power cable can’t affect the door control system to
distinguish encoder signal .
結論(Conclusion):
門(mén)機編碼器和門(mén)機馬達動(dòng)力線(xiàn)不需增加屏蔽層。
We think that don’t need to add the shield level for the motor encoder cable . 
等級:C 頁(yè)碼:3/1
版本:A 更改碼:00
蒂森克虜伯電梯(中國區制造)
工程中心
K200 門(mén)機現場(chǎng)故障解決
指導書(shū)
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
3. 機械機構問(wèn)題處理(Mechanical problem Solution ):
門(mén)機馬達同步皮帶張力太低,門(mén)機轉動(dòng)過(guò)程中導致皮帶轉動(dòng)回差和滑齒現象,導致脈沖計數
誤差。
The tesion force for moter synchronous belt is too low , it will arise the belt jump teeth and
progressive error , cause the pulse count error to the door control system.
處理方法(Solve methods):
a) 不同類(lèi)型和不同廳門(mén)寬度的 K200 門(mén)機,門(mén)機同步帶的張緊力有不同的設置要求,電梯在使
用過(guò)程中,同步帶會(huì )長(cháng)度會(huì )延長(cháng),現場(chǎng)應根據同步帶松緊度表中的張力要求,定期檢查并調整
K200 門(mén)機的張緊度符合表中規定。
Different type and deferent width K200 door system ,the synchronous belt tension force have
different value.The belt will be lengthen during using time,so the site should be adjust the tension
force in time according the synchronous bele tenson force schedule .
b) 同步帶張緊力調整方法 、張緊力檢測方法、張緊力測試工具和同步帶松緊度表請參考附件
壓縮文件 2:(同步帶張緊力測試)。
About the Adjusting method of the synchorous belt ,Measure method of the tenson force for belt,The
measure tool tension force and The synchorous belt tension force standard sheet , Please to see the
attached winrar file 2 :( 同步帶張緊力測試).
備注(Note):
同步帶張力測試工具,分公司可以根據圖紙制作,或與 BST 公司進(jìn)行采購。
The tools for the tension force examination ,can made according to the graph by the Branch ,also can
buy from BST . 
等級:C 頁(yè)碼:4/1
版本:A 更改碼:00
蒂森克虜伯電梯(中國區制造)
工程中心
K200 門(mén)機現場(chǎng)故障解決
指導書(shū)
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
現場(chǎng)跟進(jìn)事項(Need to followed by the site)!!!
正確調整擋塊位置。使廳門(mén)在完全關(guān)閉的位置時(shí),掛鉤之間的間隙在 1-2mm 之間,這樣使
皮帶轉動(dòng)過(guò)程順暢而無(wú)強大阻擋力產(chǎn)生,見(jiàn)圖(6)。
Right to adjust the position of the bar .The gap between tw hooks is 1-2mm when the door are
throughtly closed,the gap can lead the belt running smooth and havn’t cause big block
force,see( photo 6).
(圖片 6/Photo6)
4. 新時(shí)達門(mén)機變頻器軟件更新(Upgrade software for door invert by New Step):
4.1 門(mén)機變頻器軟件升級
新時(shí)達公司會(huì )采取更換變頻器控制板的方式升級門(mén)機控制軟件到最新版本。即對于版本號
FOO 顯示低于 250 15 的門(mén)機變頻器,軟件應立即升級, 具體由新時(shí)達公司提供門(mén)機變頻器主板,
于現場(chǎng)更換。請工廠(chǎng)客戶(hù)服務(wù)部門(mén)統計數量,聯(lián)系供應商并通知現場(chǎng)立即更換。具體更換注意
事項請參考附件 3-蒂森門(mén)機變頻器控制板更換。
The STEP will update the old version for K200 to the latest version by changed the inverter control
board .the inverter control board will changed immediately if the software are less than 250 15 by
New Step. It is need to statistics the quantity by the Customer Sevice Departmen,contact to the
supplier and imforma to site changed immediately. The attention please to see the attached file 3-蒂
森門(mén)機變頻器控制板更換.
間隙 1-2 毫米
等級:C 頁(yè)碼:5/1
版本:A 更改碼:00
蒂森克虜伯電梯(中國區制造)
工程中心
K200 門(mén)機現場(chǎng)故障解決
指導書(shū)
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
4.2 門(mén)機變頻器調試注意事項
1) 門(mén)機變頻器密碼(The password for door inverter):
請使用萬(wàn)能密碼是:先輸入 L6902,再輸入 H3912,而后可操作修改參數。
Please use all-purpose password:First input L6902,next input H3912,then can operate the control
parameters.
2) 特殊參數及其事項(強制)
- F35 的參數必須改為“零”,以取消門(mén)機堵轉自動(dòng)開(kāi)門(mén)功能;
F35 should be set ‘0’ and canceled the auto-opened function when the door are blocked;
- 將 F37 參數 F37.2,F37.3 改為“常閉”觸點(diǎn)類(lèi)型,將門(mén)機堵轉輸出串接到光幕回路,現場(chǎng)需要
根據附件 4-S9233 的配置更換電纜;
Change the F37.2,F37.3 to ‘NC’ in F37,connect the output signal of blocking running to the light
curtain circuit chain,please to refer the attached file 4-S9233 to change the right cable.
- 調整 MC2 控制系統 AF5A 的參數值為 3-4 秒,增大重開(kāi)門(mén)時(shí)間值。
Adjust the reopen time is 3-4 S in AF5A of the MC2 control system .
現場(chǎng)調試參數列表(Site adjustment parameter table):
功能
碼 參數名稱(chēng) 參數范圍 單位 出廠(chǎng)設置
F00 版本號+功能設定 1 / 199 / 9999 × 2501x
F04 門(mén)寬 0 ~ 60000 × 113
F08 關(guān)門(mén)到位百分比 0-15 × 8
F11 開(kāi)門(mén)啟動(dòng)低速 1 ~ 300 rpm 30
F12 關(guān)門(mén)啟動(dòng)低速 1 ~ 300 rpm 30
F13 開(kāi)門(mén)高速 1 ~ 1500 rpm 360
F14 關(guān)門(mén)高速 1 ~ 1500 rpm 315
F15 開(kāi)門(mén)停止低速 1 ~ 300 rpm 40
F16 關(guān)門(mén)停止低速 1 ~ 300 rpm 30
F17 開(kāi)門(mén)加速度 1 ~ 30 × 10
F22 開(kāi)門(mén)爬行距離 1 ~ 30 % 10 
等級:C 頁(yè)碼:6/1
版本:A 更改碼:00
蒂森克虜伯電梯(中國區制造)
工程中心
K200 門(mén)機現場(chǎng)故障解決
指導書(shū)
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
F23 關(guān)門(mén)爬行距離 1 ~ 30 % 2
F24 開(kāi)門(mén)減速位置 50 ~ 100 % 63
F25 關(guān)門(mén)減速位置 1 ~ 50 % 40
F30 開(kāi)門(mén)保持力矩大小 0 ~ 30 × 15
F31 關(guān)門(mén)保持力矩大小 0 ~ 30 × 7
F33 力矩保持時(shí)的速度 0 ~ 90 rpm 60
F34 v/f 控制時(shí)輸出力矩 0 ~ 40 % 25
F36 輸入類(lèi)型設定 00000000~11111111 × 00000000
F37 輸出類(lèi)型設定 0000 ~ 1111 × 0000
F91 初始化參數選擇 0 ~ 255 × 6
注意(CAUTION):
- 上表僅作參考,具體根據現場(chǎng)情況按安裝手冊調整。
Up sheet only for refer ,more adjust details to see the installation manual .
- 在門(mén)機同步皮帶張力調整到位的前提下,如發(fā)現門(mén)機頻繁發(fā)生自矯正慢速運行,建議在門(mén)寬自學(xué)
習后,檢查 F15 參數值,并將 F15 內的參數增大 10 或更大。
At the right adjustment of synchronous belt, if find the K200 door system do adjustment running very
frequently , we suggest to consult the parameter F15 value and decrease the value 10 or more.
- 增大/降低關(guān)門(mén)速度,需要同時(shí)增加/減小 F14, F25 的參數值。
Increase / decrease the closing speed , it need to increase /decrease the value in parameter F14 and F25
at one times .
- 增大/降低開(kāi)門(mén)速度,需要同時(shí)增加/減小 F13, F24 的參數值,
Increase / decrease the opening speed ,it need to increase /decrease the value in parameter F13 and
F24 at one times 
等級:C 頁(yè)碼:7/1
版本:A 更改碼:00
蒂森克虜伯電梯(中國區制造)
工程中心
K200 門(mén)機現場(chǎng)故障解決
指導書(shū)
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
3) 門(mén)機速度調整(Adjustment the door speed)
- 門(mén)機需要調整(復位)參數時(shí),請先撥到檢修狀態(tài);
Please turn the elevator to inspection mode when adjust (reset ) the control parameters;
- 設置 FOO=1,再根據需要修改相應的參數;
To change other parameters when needed should after to set the F00=1;
- 參數修改后請運行檢查,必要時(shí)重復上面動(dòng)作;
Please to do the test running after the parameter has been changed; try do it again when needed;
- 門(mén)機調試完畢或門(mén)機切斷電源之前,設置 F00=199 保存參數,否則修改的調試參數會(huì )在重新
上電時(shí)丟失。
After change the door control parameter or turn off the door power ,it need to set F00=199 to save
the changed parameter, otherwise the parameter will be lost after the power turn on next.
4) 開(kāi)、關(guān)門(mén)到位力矩保持調整 (Keeping torque of end position adjustment)
- 改變開(kāi)、關(guān)門(mén)力距保持的力,可以通過(guò)修改 F30、F31、F33 等參數值;
It can be changed the value of parameter F30,F31,F33 to change the keeping torque of door end
position;
- 增大保持力時(shí),要同時(shí)減少保持速度;反之,減小保持力,要同時(shí)增加保持速度。
Increase the keeping torque value ,need to decrease the keep speed;on the other hand , decrease
the keeping torque value ,need to increase the keep speed at one time.
 批 準 審 核 編 制
Pietz 2009.06.23 楊榮明 2009.06.23 李必春 2009.06.23 


文件下載:點(diǎn)擊下載EC019-SS K200門(mén)機現場(chǎng)故障解決指導書(shū) (點(diǎn)擊查看下載口令
    下載申明:(1)倍加信梯控提供的EC019-SS K200門(mén)機現場(chǎng)故障解決指導書(shū)資料來(lái)源于網(wǎng)絡(luò )收集整理,并免費提供下載EC019-SS K200門(mén)機現場(chǎng)故障解決指導書(shū)不收取任何費用,若發(fā)現您的權益受到侵害,請立即聯(lián)系我們,我們會(huì )立即刪除EC019-SS K200門(mén)機現場(chǎng)故障解決指導書(shū)資料。(2)倍加信梯控提供的EC019-SS K200門(mén)機現場(chǎng)故障解決指導書(shū)資料僅供用戶(hù)學(xué)習和參考,用戶(hù)如果使用下載的EC019-SS K200門(mén)機現場(chǎng)故障解決指導書(shū)資料造成任何損失與倍加信無(wú)關(guān),EC019-SS K200門(mén)機現場(chǎng)故障解決指導書(shū)資料最終以版權廠(chǎng)家提供原廠(chǎng)資料為準。(3)倍加信梯控免費提供大量蒂森電梯技術(shù)資料下載,歡迎收藏本站,底部右下角提供了搜索功能,倍加信人臉識別梯控、IC刷卡梯控、二維碼梯控、指紋識別梯控、語(yǔ)音梯控、CPU梯控、ID卡梯控、手機乘梯、機器人乘梯等廣泛應用于蒂森電梯,歡迎掃碼二維碼加個(gè)微信咨詢(xún)或備用,再次感謝您在倍加信梯控免費下載蒂森電梯EC019-SS K200門(mén)機現場(chǎng)故障解決指導書(shū)。